Kalıp Döküm MakinalarıBUHLER H 800B VERSION 6
Maharashtra, Hindistangenel bakış
Marka
model
kimlik numarası
626715
Durum
Kullanılmış - Mükemmel
Yıl
1996
seri numarası
102623349
Yer
Maharashtra
Hindistan
Hindistan
Stok #
1378
spec Sheet
The platen size of Buhler 800B version 6 is bigger than usual.
Accessories : Dosing Furnace
( You don’t needle ladle with this furnace) , Kawasaki Robot and Wollin
YOM 1996 and actual went in production in 1998
TECHNICAL DATA:
Locking Force (Strain Gauge Tested) kn 9200
Injection Force, Consolidation Phase (Adjustable) kn 650-265 1)
Plunger Stroke mm 580
Injection Positions (Standard) mm 0, -50, -300, -350
Ejection force kn 340
Ejector stroke (adjustable) mm 175
Dimensions of fixed die platen (H X V ) mm 1410 x 1590
Dimensions of moving die platen (H X V ) mm 1410 x 1410
Space between tie bars mm 900 x 900
Tie bar diameter mm 180
Min. die height mm 330
Max. die height mm 1050
Stroke of moving platen mm 900
Free cycles per hour n/h 300
Rated installed capacity kw 55
Machine area L X W (incl. safety gates) m 9082 x 3.52
Machine height m 3.3
Machine weight, ready for production kg 40900 ca.
Dimensions of the control cabinet L X W X H (IC) m 1.4 x.4x 1.65
1) AccessoryEequipment: (DATACESS) m 1.2 x .5 x 1.805
Injection force, consolidation phase (adjustable) kN 800 - 265
PRODUCTION DATE (Standard injection unit)
PLUNGER DIAMETERS MM 70 80 90 100 110 120 130 140
Theoretical shoot volume(DIN 24480) cm3 1488 1944 2460 3037 3674 4373 5132 5952
Max. shot weight fro A1* kg 4.2 5.5 6.9 8.5 10.3 12.3 14.4 16.7
Max. specific casting pressure bar 1690 1293 1021 828 648 574 489 422
Max. projectted area ** at max. specific casting pressure cm2 544 711 901 1111 1419 1602 1881 2180
*The max. shot weight is calculated :
Plunger stroke x plunger area x 0.75 x density
Density for aluminium (A1) =2.5 g/cm3
(Multiply by 0.65 for magnesium alloys, by 2.5 for zinc alloys and by 3.2 for copper base alloys)
**Max. theoretical projected area on max .specific injection pressure, without consideration of core locking and dynamic part of injection process.